<11006749 001>
Page 37 of 50
Inside enclosure
near power
14.4
Outside enclosure
near power
14.1
Panel surface
27.4
Button
2.9
Ambient (ºC)
23.8
Winding temperature rise measurements
N
Ambient temperature t1 (
o
C) .................................. :
—
Ambient temperature t2 (
o
C) .................................. :
—
13.1 TABLE: Clearances and creepage distances in accordance with 13.2
P
clearance cl and creepage
distance dcr at/of:
Up
(V)
U r.m.s.
(V)
required cl
(mm)
cl
(mm)
required
dcr (mm)
dcr
(mm)
Hazardous live components
(with 2N)
→
earthed metal
chassis
420 250
2.0
↓
2.5
↓
-
HS1 → metal chassis
7.1
7.1
-
Primary HS1 top → metal
chassis
7.7
7.7
Hazardous live trace
→
earthed metal chassis
420 250
2.0
↓
2.5
↓
-
Primary trace → metal
chassis
8.0
8.0
Hazardous live trace
→
secondary trace
420 250
4.0
↓
5.0
↓
-
Primary trace →
trace
21.6
21.6
Notes:
1. Internal wires were fixed on PCB by quick connector. Also used cable tie, hook and PVC tube to keep the
double insulation to Hazardous live parts.
2. Cl and cr. in the SPS was already considered during the component approval.
14 TABLE: list of critical components and materials