Page 22 of 50
IEC/EN 60065
Clause RequirementTest Result - Remark Verdict
19.4 Edges or corners not hazardous Edges or corners are
smoothed.
P
19.5 Glass surfaces with an area exceeding 0,1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
No glass surfaces.
N
19.6 Wall or ceiling mountings adequate
N
20 RESISTANCE TO FIRE
P
20.1 Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
Not applied.
N
b) Exemption for small components as defined in
20.1
All capacitors smaller than
1750mm
2
, IC, transistors and
photo couplers are mounted on
a PCB with V-0 (or better).
P
20.1.1 Electrical components meet the requirements of
Clause 14 or 20.1.4
See sub clause 14 and 20.1.4.
P
20.1.2 Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire
enclosure, not contributing to the spread of fire
Internal PVC wiring working at
voltage less then 4 kV.
N
20.1.3 Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
See below.
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
PCB with V-0 or better material
used for power supply.
P
20.1.4 Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
Plastic enclosure material is
rated with flammability class V-
0.
P
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N
20.2 Fire enclosure
N
20.2.1 Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
Less than 4 kV.
N