<11006749 001>
Page 16 of 50
IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
N
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
N
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N
14.6.2 Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
Approved switches are used.
N
14.6.3 Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
Ditto.
N
14.6.4 Switch tested to 14.6.1 b) has adequate dielectric
strength
Ditto.
N
14.6.5 Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
No mains socket outlets.
N
Socket outlet current marking correct
N
14.7 Safety interlocks No safety interlocks.
N
Safety interlocks to 2.8 of IEC 60950
N
14.8 Voltage setting devices No voltage setting devices.
N
Voltage setting device not likely to be changed
accidentally
N
14.9 Motors No motor provided.
N
14.9.1 Endurance test on motors
N
Motor start test
N
Dielectric strength test
N
14.9.2 Not adversely affected by oil or grease etc.
N
14.9.3 Protection against moving parts
N
14.9.4 Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
N
14.10 Batteries See below.
P
14.10.1 Batteries mounted with no risk of accumulation of
flammable gases
2 “AAA” non-rechargeable
batteries used in remote
controller.
P