Acer AT2605 Manual do Utilizador Página 18

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 54
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 17
<11006749 001>
Page 14 of 50
IEC/EN 60065
Clause RequirementTest Result - Remark Verdict
Shielded by a barrier to V-0 or metal ...................... :
Electrolytic can type capacitor
is having a metal case.
P
14.3 Inductors and windings In approved SPS and DC/AC
inverter.
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
N
14.3.1 Transformers and inductors marked with
manufacturer's name and type ............................... :
In approved SPS and DC/AC
inverter.
P
Transformers and inductors separately approved . :
N
14.3.2 General Isolation transformer used in
approved SPS.
P
14.3.3 Constructional requirements Ditto.
P
14.3.3.1 Clearances and creepage distances comply with
clause 13
Ditto.
P
14.3.3.2 Transformers meet the constructional
requirements
Ditto.
P
14.3.4.1 Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
N
Coil formers and partition walls > 0,4 mm
N
14.3.4.2 Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
Class II transformer. Used in
approved SPS.
N
14.3.4.3 Separating transformers with at least basic
insulation
No separating transformer.
N
14.3.5.1 Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
In approved SPS.
P
Coil formers and partition walls > 0,4 mm Ditto.
P
14.3.5.2 Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class II transformer used in
approved SPS.
N
Winding wires connected to protective earth have
adequate current-carrying capacity
Ditto.
N
14.4 High voltage components No component operating at
voltage exceeding 4kV.
N
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
Ditto.
N
Vista de página 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 53 54

Comentários a estes Manuais

Sem comentários