IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict
16.5 Adequate strain relief on external flexible cords Detachable power supply cord
is used.
N
Not possible to push cord back into equipment
N
Strain relief device unlikely to damage flexible cord
N
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
N
16.6 Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
N
16.7 Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60320-1
The unit is not transportable
apparatus.
N
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
Ditto.
N
17 ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS
P
17.1 Torque test to table 20: See below.
P
- screws into metal: 5 times Metal screw (Ø3.9mm or
Ø2.9mm) for fastening of
internal metal enclosure.
P
- screws into non-metallic material: 10 times Metal screw (Ø3.9mm or
Ø2.9mm) for fastening of
plastic enclosure.
P
17.2 Correct introduction into female threads in non-
metallic material
No screws into female threads
in non-metallic.
N
17.3 Cover fixing screws: captive No reduction of clearance or
creepage distance
P
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
No hazard when replaced by a
screw whose length is 10 times
nominal diameter.
P
17.4 No loosening of conductive parts carrying a current
> 0,2 A
All conductive fire parts are
fixed on PCB by at least two
soldering points.
P
17.5 Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
No contact pressure by screws.
N