<11006749 001>
Page 6 of 50
IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict
5.3 Use of triangle with exclamation mark
Provided in approved SPS and
panel with inverter.
P
5.4 Instructions for use
User’s manual provided in
English language. Version of
other languages will be
provided when national
approval.
P
5.4.1 Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled with
liquid, etc.
State on the User manual.
P
Hazardous live terminals, instructions for wiring No hazardous live terminals.
N
Instructions for replacing lithium battery No lithium batteries used.
N
Instructions for modem if fitted No modem used.
N
Class I earth connection warning Stated in user’s manual.
P
Instructions for multimedia system connection Stated in user’s manual.
P
Special stability warning for fixed installation
N
5.4.2 Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
Applicance inlet was provided
and remain readily operable.
P
Instructions for permanently connected equipment Not permanently connected
equipment.
N
6 HAZARDOUS RADIATION
N
6.1 Ionizing radiation < 36 pA/kg (0,5 mR/h) No CRT used.
N
6.1
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
Ditto.
N
6.2 Laser radiation, emission limits to IEC 60825-1 ..... :
No laser.
N
Emission limits under fault conditions .................... :
Ditto.
N
7 HEATING UNDER NORMAL OPERATING CONDITIONS
P
7.1 Temperature rises not exceeding specified values,
no operation of fuse links
(See appended table)
P
7.1.1 Temperature rise of accessible parts (See appended table)
P
7.1.2 Temperature rise of parts providing electrical
insulation
(See appended table)
P
7.1.3 Temperature rise of parts acting as a support or as
a mechanical barrier
(See appended table)
P
Comentários a estes Manuais