IEC/EN 60065
Clause RequirementTest Result - Remark Verdict
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
Green/yellow wire is connected
from inlet to metal chassis.
Green/Yellow wire is fixed
reliably on the metal chassis
with ring terminal, starwasher
and screw.
P
Class I supply equipment with non-hazardous live
output voltage: output circuit not connected to earth
N
Protective earth conductors correctly coloured Green/yellow wire provided.
P
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
Appliance inlet used.
N
Protective earth terminal resistant to corrosion All safety earthing connection
in compliance with annex F.
P
Earth resistance test: < 0,1
at 25 A ................... :
See appended table.
P
15.3 Terminals for external flexible cords and for
permanent connection to the mains supply
Approved class I appliance
inlet provided.
N
15.3.1 Adequate terminals for connection of permanent
wiring
N
15.3.2 Reliable connection of non-detachable cords:
N
Not soldered to conductors of a printed circuit
board
N
Adequate clearances and creepage distances
between connections should a wire break away
N
Wire secured by additional means to the conductor
N
15.3.3 Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
N
15.3.4 Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
N
Clamping of conductor and insulation if not
soldered or held by screws
N
15.3.5 Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current
of the equipment
N
15.3.6 Terminals to 15.3.3 have sizes required by table 16
N
15.3.7 Terminals clamp conductors between metal and
have adequate pressure
N
Terminals designed to avoid conductor slipping out
when tightened or loosened
N