Acer Altos G530 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Servidores Acer Altos G530. Acer Altos G530 User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Acer Altos G530 Series

Acer Altos G530 SeriesUser’s Guide

Página 2

xIndex 179

Página 3 - FCC notice

4 BIOS setup90Fourth IDE MasterSpecifies the current configuration of the IDE device connected to the master port of the fourth IDE channel. Press En

Página 4 - Laser compliance statement

91Mixed P-ATA / S-ATAThe Mixed P-ATA/S-ATA submenu lets you specify the channel for the Parallel ATA Primary channel and Serial ATA device. Par

Página 5 - Important safety instructions

4 BIOS setup92Primary/Secondary/Third/Fourth IDE Master/SlaveThese items let you select the IDE hard disk parameters that the system supports. P

Página 6

93S.M.A.R.T. Indicates if the selected device supports S.M.A.R.T. (Self-Monitoring, Analysis and Reporting Technology) function. Type Selects the driv

Página 7 - Contents

4 BIOS setup94DMA Mode Selects DMA (Direct Memory Access) mode. AutoSWDMA0SWDMA1SWDMA2MWDMA0MWDMA1MWDMA2UDMA0UDMA1UDMA2UDMA3UDMA4UDMA5S.M.A.R.T. Enab

Página 8 - 4 BIOS setup 77

95Floppy ConfigurationThe Floppy Configuration submenu displays the type of floppy drive installed in the server. Parameter Description OptionFlop

Página 9

4 BIOS setup96Super I/O ConfigurationThe Super I/O Configuration submenu lets you define the parameter settings for the system’s serial port. Para

Página 10 - Index 179

97USB ConfigurationThe USB Configuration submenu lets you specify settings for USB devices. Parameter Description OptionUSB Function Enables or disa

Página 11 - 1 System tour

4 BIOS setup98USB Mass Storage Device ConfigurationThe USB Mass Storage Device Configuration submenu lets you specify settings for a USB mass storage

Página 12

99PCI ConfigurationThe PCI Configuration submenu lets you specify settings that are related to the onboard controllers. Parameter Description OptionO

Página 14 - 1 System tour

4 BIOS setup100Onboard NIC 2 (Right) Enables or disables the onboard NIC2 (10Base-T/ 100Base/ 1000 Base network interface controller).EnabledDisabled

Página 15 - Power supply

101Memory ConfigurationThe Memory Configuration submenu provides information about the DIMMs installed in DIMM slots 1A, 1B, 2A, and 2B. Paramet

Página 16 - Front bezel

4 BIOS setup102Memory RetestWhen Enabled, BIOS will activate and retest all DIMMs on next boot. Note: This parameter will automatically reset to Disa

Página 17 - Front panel

103BootThe Boot menu allows you to set the drive priority during system bootup. It also displays information about the installed storage devices.Press

Página 18

4 BIOS setup104Boot Settings ConfigurationThe Boot Settings Configuration submenu lets you specify the preferred settings for system bootup. Paramete

Página 19 - Hot-plug HDD LED indicators

105Bootup Num-LockActivates the Numeric Lock function upon booting. OffOn PS/2 Mouse SupportEnable this parameter if you intend to use a mouse or trac

Página 20 - Rear panel

4 BIOS setup106Boot Device PriorityThe Boot Device Priority submenu lets you specify the boot search sequence during the POST process. BIOS setup wil

Página 21

107Hard Disk DrivesThe Hard Disk Drives submenu lets you specify the devices that will be considered as the primary and secondary hard drives. 4th

Página 22 - Rear panel LED indicators

4 BIOS setup108Removable DrivesThe Removable Drives submenu displays the type of removable devices installed in the system.

Página 23 - Internal components

109CD/DVD DrivesThe CD/DVD Drives submenu displays the type of ATAPI CD-ROM installed in the system.

Página 24 - System boards

The Acer Altos G530 server is a powerful dual-processor system loaded with a host of new and innovative features. The system offers a new standard for

Página 25

4 BIOS setup110SecurityThe Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. Paramet

Página 26

111Setting the Administrator/User password:1 Use the up/down keys to highlight a password parameter (Administrator Password or User Password) then pre

Página 27 - Jumper settings

4 BIOS setup112Removing the User password1 Use the up/down keys to highlight the Clear User Password parameter then press Enter.2 Enter the current p

Página 28 - * and NC = No connection

113Server The Server menu allows you to configure appropriate settings for monitoring the server. Parameter Description OptionSystem ManagementPre

Página 29 - Backplane board layout

4 BIOS setup114System ManagementThe System Management submenu displays specific system information. The screen below is for your reference only, syst

Página 30

115Serial Console FeaturesThe Serial Console Features submenu allows you to configure the serial port settings. Parameter Description OptionBIOS Redir

Página 31 - SATA backplane board layout

4 BIOS setup116Terminal Type Specify the type of remote console. VT100+VT-UTF8PC-ANSIACPI Redirection PortSpecify the serial port where an ACPI (Adv

Página 32

117Event Log ConfigurationThe Event Log Configuration submenu allows you to record and monitor events that occur in the system (e.g. system temperatur

Página 33 - 2 System setup

4 BIOS setup118ECC Error Logging Enables or disables the ECC (Error Correcting Code) event logging function of the system. ECC tests the accuracy of

Página 34

119ExitThe Exit menu displays the various options to quit from the BIOS setup utility. Highlight any of the exit options then press Enter. Parameter

Página 35 - Setting up the system

3Features summaryListed below are the system’s key features:Processor• Single or Dual Intel® Xeon™ processors with 1MB or 2MB L2 cache and 800 MHz fro

Página 36 - Connecting peripherals

4 BIOS setup120Load Setup DefaultsLoads the default settings for all BIOS setup parameters. Setup Defaults are quite demanding in terms of resources

Página 38 - 2 System setup

This chapter provides possible solutions for specific problems. If you cannot correct the problem, contact your local Acer representative or authorize

Página 39 - Power-on problems

123Resetting the systemBefore going through in-depth troubleshooting, attempt first to perform reset the system using one of the methods below. To do

Página 40 - Configuring the system OS

5 Troubleshooting124Problems following initial system installationProblems that occur at initial system startup are usually caused by an incorrect in

Página 41 - Server setup

125First steps checklist• AC power available at the wall outlet?• Are the power supplies plugged in? Check the AC cable(s) on the back of the chassis

Página 42 - Turning off the system

5 Troubleshooting126Hardware diagnostic testingThis section provides a more detailed approach to identifying a hardware problem and locating its sour

Página 43 - 3 System upgrade

127Confirming loading of the OSOnce the system boots up, the operating system prompt appears on the screen. The prompt varies according to the operati

Página 44

5 Troubleshooting128• Make sure the FDD and signal cables are properly connected.• Check that relevant switches and jumpers for the FDD are set corre

Página 45 - Installation precautions

129CD drive activity indicator does not light.Do the following:• Make sure the power and signal cables are properly installed. • Check that relevant s

Página 46 - 3 System upgrade

1 System tour4Optional media storage • Hot-plug HDD cage• Supports up to four 80-pin Ultra320 SCSI hard disk drives• Supports up to four SATA 150/300

Página 47 - Opening the server

5 Troubleshooting130Network status indicator does not light.Do the following:• Check the cabling and network equipment to make sure that all cables a

Página 48 - Removing the front bezel

131No characters appear on the screen.Check the following:• Is the keyboard functioning? Test it by turning the “Num Lock” function on and off to make

Página 49 - 1 Open the bezel door

5 Troubleshooting132BIOS error messagesWhen a recoverable error occurs during POST, BIOS will display an error message describing the problem. The fo

Página 50

133Error message DescriptionStorage device BIOS messagesPrimary Master/Slave Hard Disk ErrorSecondary Master/Slave Hard Disk Error3rd Master/Slave Ha

Página 51

5 Troubleshooting134Error message DescriptionVirus related BIOS messageBootSector Write !! A software attempting to write to a drive’s boot sector h

Página 52

135Static Resource Conflict Two or more Static Devices are trying to use the same resource space (usually Memory or I/O).PCI I/O conflict PCI ROM conf

Página 53

5 Troubleshooting136Warning! EHCI controller disabled. It requires 64bit data support in the BIOS.The EHCI controller is disabled because of incorrec

Página 54

137POST error messagesThe following table lists the error codes and associated conditions that may occur during the POST portion of the BIOS. Error co

Página 55

5 Troubleshooting1380046 DMA-2 error0047 Unknown BIOS error. Error code = 147 (this is really a PMM_MEM_ALLOC_ERR)0048 Password check failed0049 Unkn

Página 56

1390150 BSP processor failed BIST0160 Processor missing microcode – P00161 Processor missing microcode – P10180 BIOS does not support current stepping

Página 57

5Graphic interface•ATI Rage® XL chipset with 8MB SDRAM I/O ports• Front panel• Two USB 2.0 ports•Rear panel• PS/2 keyboard and mouse port• Two USB 2.0

Página 58

5 Troubleshooting1408504 Bad or missing memory in slot 3B8505 Bad or missing memory in slot 2B8506 Bad or missing memory in slot 1B8508 All memory ma

Página 59

141POST beep codesThe following table lists the error beep codes. Prior to system video initialization, BIOS uses these beep codes to inform users of

Página 60

5 Troubleshooting142Troubleshooting BIOS beep codesThe following table lists the possible beep codes thay may occur while using the system and is fol

Página 61

Appendix A: System management utility

Página 62

This appendix shows you how to install the ASM software package and gives information about the software program and utilities bundled with your serve

Página 63

145Your Altos G5350 server supports the following system management utilities:• ASM (Acer Server Manager) This utility allows you to spot errors or po

Página 64

Appendix A: System management utility146ASMAcer Server Manager is a server management tool. It is specially designed to help spot errors or potential

Página 65 - Replacing the CD-ROM drive

147System setupMake sure that the system meets the requirements listed above before proceeding. You may also want to change your screen resolution to

Página 66

Appendix A: System management utility148To launch the program, on the Windows taskbar click on the Start button, point to Programs, select Acer Serve

Página 67 - Installing 5.25-inch drives

149RAID configurationCaution! Using the RAID configuration utility erases all data previously saved in the hard drives. Make sure that you backup imp

Página 68

1 System tour6External and internal structureFront bezel No. Component1 Side panel release button2 Security keylock3 Front panel LED indicator4 Beze

Página 69 - Upgrading the processor

Appendix A: System management utility150

Página 70 - Installing the HSF assembly

Appendix B: Acer Altos G530rack installation guide

Página 71 - Removing the HSF assembly

This appendix shows you how to set up the Altos G5350 server in a rack mount configuration.

Página 72

153Setting up the system rackImportant! Observe the electrostatic discharge (ESD) precautions indicated on page 35 when perfoming the following proced

Página 73 - Removing the CPU

Appendix B: Acer Altos G530 rack installation guide154• Elevated operating ambient temperature The maximum operating temperature of the system is 35

Página 74 - Upgrading the system memory

155System rack installation The Altos G5350 server system can also be mounted in a rack-model position. A rack mount kit is available for customers wh

Página 75 - Memory Interleave

Appendix B: Acer Altos G530 rack installation guide156Vertical mounting hole patternThe four vertical rails of the system rack contain mounting holes

Página 76

157Screw types usedThe following screws are used in the assembly of the Altos G5350 system and bundled rack-mountable components: Screw type and part

Página 77 - Removing a DIMM

Appendix B: Acer Altos G530 rack installation guide158Installing the system into the rackCaution! To minimize the chances of injuries, make sure tha

Página 78 - Installing a DIMM

1592 Remove the inner rails from the mounting rails.Note: The rack mount kit contains a pack of screws, two sets of side handles, rack brackets and m

Página 79

7Front panel No. Icon Component Description1DVD/CD-ROM drive Stop/Eject button Press this button to open the CD drive tray.2DVD/CD-ROM drive activit

Página 80 - Installing an expansion card

Appendix B: Acer Altos G530 rack installation guide1603 Attach the inner rails to the mounting shelf.(1) Align the inner rails to both sides of the m

Página 81

161(2) Tighten the four thumbscrews on the rear of the mounting shelf (2).5 Install the rack brackets to the rack by following the steps below:(1) Al

Página 82 - Upgrading the power supply

Appendix B: Acer Altos G530 rack installation guide1626 Install the M6 cage nuts (see page 157) into the rail.(1) Insert the lower lip of the cage nu

Página 83

1637 Install the mounting rails to the rack by using four M6 x L10 metal screws (see page 157) for each mounting rail. 8 Extend the middle sliding pi

Página 84

Appendix B: Acer Altos G530 rack installation guide1649 Install the server shelf assembly into the rack.Caution! To avoid personal injury, care shou

Página 85

165(1) Attach the cable arm to the rear of the system using two M4 x L8 metal screws and nuts (see page 157). (2) Install two cage nuts into the rail

Página 86

Appendix B: Acer Altos G530 rack installation guide166(4) Connect the power, peripheral and networking cables into their appropriate ports (1). Refer

Página 87 - 4 BIOS setup

Appendix C: SATA RAID configuration

Página 88 - BIOS parameters

This appendix shows you how to create a RAID volume in your SATA drives.

Página 89 - BIOS setup

169Configuring the SATA RAIDThis section shows how to create a RAID 1 (mirror) volume with the onboard SATA RAID function. This feature requires the i

Página 90 - Entering BIOS setup

1 System tour88 Hard disk activity indicator 2Indicates the status of the system hard drive. 9 LAN activity indicator 3Indicates an active link on th

Página 91

Appendix C: SATA RAID configuration170Creating a RAID 1 volume 1 After rebooting the server, press Ctrl+E to enter the SATA RAID Configuration scree

Página 92 - 4 BIOS setup

171(c) Press Ctrl+Alt+Del to reboot the server. 8 Install an Operating System to the RAID array.

Página 93

Appendix C: SATA RAID configuration172

Página 94 - Advanced

Appendix D: SCSI RAID configuration

Página 95 - Processor Configuration

This appendix shows you how to create a RAID volume in your SCSI drives.

Página 96

175Configuring the SCSI/SCSI RAID HBAThis section shows how to create a RAID 1 (mirror) volume. This feature requires the installation or presence of

Página 97

Appendix D: SCSI RAID configuration176If you change the settings in the Hot Spare field, the following messages appear:WARNING: Data on drive will be

Página 98 - IDE Configuration

177Creating a RAID 1 volume 1 After rebooting the server, press Ctrl+M to enter the MegaRAID Configuration screen. The Management menu appears.2Selec

Página 99

Appendix D: SCSI RAID configuration1785 When initialization is complete, press any key to continue.6 Press Esc to return to the Management menu.7 To

Página 100

179IndexAAcer Server Manager (ASM)system requirementsASM Agent 146ASM Console 146system setup 147install ASM Agent 147install ASM Console

Página 101 - Mixed P-ATA / S-ATA

9Front panel LED indicatorsBelow table lists the LED states on the front panel. Hot-plug HDD LED indicators Below table lists the possible disk drive

Página 102

180MegaRAID utility 176assign hot spare 177create RAID 1 177initialize RAID volume 177RAID volumeinitialization 176SATA HBA utility

Página 103

Changes may be made periodically to the information in this publication without obligation to notify any person of such revision or changes. Such cha

Página 104

1 System tour10Rear panel No. Icon Component Description1Power supply module bay Allows installation of a redundant and non-redundant redundant powe

Página 105 - Floppy Configuration

114 PS/2 keyboard portConnects to a PS/2 keyboard.5 VGA/monitor portConnects to monitors.6 Serial port Connects to serial devices.7 Gigabit LAN ports

Página 106 - Super I/O Configuration

1 System tour12Rear panel LED indicatorsBelow table lists the LED states on the LAN port. LED Green Yellow StatusLink On — • Indicates 100MBps Ethern

Página 107 - USB Configuration

13Internal components No. Component1Power supply module (600 or 610-watts) 11 The system supports a redundant or non-redundant power supply module

Página 108

1 System tour14System boardsMainboard layoutThe mainboard becomes accessible once you open the system. It should look like the figure shown below.

Página 109 - PCI Configuration

15No. Code Description1 USB_1~2 USB ports2 MS/KB Top: PS/2 mouse portBottom: PS/2 keyboard port3 SERIAL A Serial A port4 VGA VGA/monitor port5 JA2 NIC

Página 110

1 System tour1621 SATA_A1- A2 SATA connectors22 HSBP_B Hot-plug backplane connector23 J38 Front panel LED connector24I2CI2C connector (reserved for A

Página 111 - Memory Configuration

17Jumper settingsJ17 jumper The J17 jumper provides a total of 3-pin blocks that are used to configure several system recovery and update options. The

Página 112

1 System tour18The following below lists the pin-out of the J38 header. * and NC = No connectionPin no. Signal name Pin no. Signal name1 ACPI LED gm

Página 113

19Backplane board layoutThe backplane board attached to the four-bay hot-plug HDD cage provides a convenient interface between the SCSI or SATA drives

Página 114 - Boot Settings Configuration

iiiNoticesFCC noticeClass A devices do not have an FCC logo or FCC IDE on the label. Class B devices have an FCC logo or FCC IDE on the label. Once th

Página 115

1 System tour206 J3 LED indicator jumperJumper setting:Short 1-2 — Link LED onShort 2-3 — Link LED dark7 SAF-TE ID SAF-TE ID jumperJumper setting:Sh

Página 116 - Boot Device Priority

21SATA backplane board layout No. Code Description1 SATA HDD connectors2 SAF-TE heartbeat LED and Manufacturing function jumper3 JP2 Debug connector4

Página 117 - Hard Disk Drives

1 System tour227 792D_ID1 792D_ID1 ADDR select jumperJumper setting:Short 1-2 — 5EH (default)Short 2-3 — 5AH8 J3 IPMB (Intelligent Platform Managemen

Página 119 - CD/DVD Drives

This chapter gives you instructions on how to set up the system. Procedures on how to connect peripherals are also explained.

Página 120 - Security

25Setting up the systemPre-installation requirementsSelecting a siteBefore unpacking and installing the system, select a suitable site for the system

Página 121

2 System setup26Connecting peripheralsRefer to the illustration below for specific connection instructions on the peripherals you want to connect to

Página 122 - Removing the User password

27Turning on the systemAfter making sure that you have properly set up the system and connected all the required cables, you can now power on the syst

Página 123

2 System setup28The system starts up and displays a welcome message on the monitor. After that, a series of power-on self-test (POST) messages appear

Página 124 - System Management

29Power-on problemsIf the system does not boot after you have applied power, check the following factors that might have caused the boot failure.• The

Página 125 - Serial Console Features

ivNotice: Shielded cablesAll connections to other computing devices must be made using shielded cables to maintain compliance with FCC regulations.No

Página 126

2 System setup30Configuring the system OSThe Altos G530 comes with Acer EasyBUILDTM that allows you to conveniently install your choice of operating

Página 127 - Event Log Configuration

31Server setup Aside from its tower configuration, the Altos G530 server system can also be mounted in a rack-model position. A rack mount kit is avai

Página 128

2 System setup32Turning off the systemThere are two ways by which you can turn off the server. These include:To turn off the server, on the Windows t

Página 129

3 System upgrade

Página 130

This chapter discusses the precautionary measures and installation procedures you need to know when upgrading the system.

Página 131 - 5 Troubleshooting

35Installation precautionsBefore you install any server component, we recommend that you read the following sections. These sections contain important

Página 132

3 System upgrade36Warning! Failure to properly turn off the server before you start installing components may cause serious damage. Do not attempt t

Página 133 - Resetting the system

37Opening the serverCaution! Before you proceed, make sure that you have turned off the system and all peripherals connected to it. Read the “Pre-ins

Página 134 - 5 Troubleshooting

3 System upgrade38Opening the bezel doorA security lock secures the bezel door to protect the system unit from unauthorized access. To open the beze

Página 135 - First steps checklist

39Removing the HDD cage bay cover1 Open the bezel door. 2 Push down the HDD cage bay cover (1). 3 Detach the HDD cage bay cover from the front bezel

Página 136 - Hardware diagnostic testing

vImportant safety instructionsRead these instructions carefully. Save these instructions for future reference.1 Follow all warnings and instructions m

Página 137 - Confirming loading of the OS

3 System upgrade40Configuring the four-bay HDD cageThis section explains how to install a four-bay hot-plug HDD cage as well as procedures on how to

Página 138

41To install the hot-plug SCSI HDD cage: 1 Observe the ESD precautions and pre-installation instructions described on page 35. 2 Remove the HDD cage

Página 139 - CD drive cannot read a CD

3 System upgrade42(1) Slide the cage into the chassis with the backplane board facing the rear of the chassis. The cage is locked to the chassis with

Página 140

43(2) SCSI HDD power cables 5 Observe the post-installation instructions described on page 36.Important: When you are detaching the hot-plug HDD cag

Página 141

3 System upgrade44To install the easy-swap SCSI HDD cage: The easy-swap SCSI HDD cage is an optional four-bay internal HDD enclosure without a SCSI

Página 142 - BIOS error messages

45(2) SCSI HDD power cables 5 Observe the post-installation instructions described on page 36.Important: When you are detaching the easy-swap cage f

Página 143

3 System upgrade46To install the hot-plug SATA HDD cage: 1 Observe the ESD precautions and pre-installation instructions described on page 35.2 Remo

Página 144

474 Install the hot-plug cage. (1) Slide the cage into the chassis. The cage is locked to the chassis with an audible click. 5 Connect the following c

Página 145

3 System upgrade48(2) Attach the system’s power cable to the SATA power cable connector on the backplane board (2).Note: The SATA RAID data cables m

Página 146

49To install the easy-swap SATA HDD cage: The easy-swap SATA HDD cage is an optional four-bay internal HDD enclosure without a SATA backplane board.1

Página 147 - POST error messages

vid If the product does not operate normally when the operating instructions are followed. Adjust only those controls that are covered by the operatin

Página 148

3 System upgrade50(1) Slide the cage into the chassis. The cage is locked to the chassis with an audible click. (2) Locate and attach the power (1) a

Página 149

51Important: When you are removing the easy-swap cage from the chassis, make sure to first remove all cables attached to the hard disks.6 Change the

Página 150

3 System upgrade52Removing the four-bay HDD cage1 Observe the ESD precautions and pre-installation instructions described on page 35.2 Disconnect the

Página 151 - POST beep codes

53Installing an additional hard disk into the HDD cage carrierNote: To purchase a hard disk carrier, contact your local Acer representative. Importan

Página 152

3 System upgrade542 Install a hard disk on the hard disk carrier (1), then secure it with the four screws that came with the hard disk carrier (2). 3

Página 153 - Appendix A: System

55Replacing the CD-ROM drive1 Observe the ESD precautions and pre-installation instructions described on page 35.2 Disconnect the power and IDE cables

Página 154

3 System upgrade564 Install a new 5.25-inch drive into the drive bay (1), then push the lever in the direction of the lock icon (2). 5 Connect the

Página 155

57Installing 5.25-inch drivesThe two empty 5.25-inch drive bays allow you to install additional drives such as another backup hard drive, CD-ROM drive

Página 156 - System requirements

3 System upgrade583 Install a tape drive into the drive bay (1), then push the lever in the direction of the lock icon (2). 4 Connect the power an

Página 157 - System setup

59Upgrading the processorThis section includes instructions for installing and removing a processor and heat sink fan (HSF) assembly. Installing the C

Página 158

ContentsNotices iiiFCC notice iiiLaser compliance statement ivImportant safety instructions v1 System tour 1Features summary 3External and internal

Página 159 - RAID configuration

3 System upgrade606 Press the retainer lever down to lock the CPU in place (2).Installing the HSF assembly1 Apply thermal grease.Apply approximately

Página 160

61(1) Align the heat sink fan assembly to the CPU (1). (2) Using a screwdriver, tighten the heatsink’s four screws to secure it to the mainboard (2).

Página 161 - Appendix B: Acer Altos G530

3 System upgrade622 Disconnect the CPU fan cable from its mainboard connector. 3 Loosen the four screws that hold the HSF assembly to the mainboard (

Página 162

63Removing the CPU1 Pull the CPU socket retainer lever to a fully open, upright position (1).2 Pull out the CPU from the socket (2).

Página 163 - Setting up the system rack

3 System upgrade64Upgrading the system memoryThis section includes instructions for removing and installing a memory module. Altos G530 has four DDR2

Página 164

65• Both DIMMs in a bank must be identical (same manufacturer, CAS latency, number of rows, columns and devices, timing parameters, etc.). Although DI

Página 165 - System rack installation

3 System upgrade66Altos G530 supports memory sparing function. To provide a more fault tolerant system, Altos G530 includes special hardware to suppo

Página 166

67Removing a DIMMBefore you can install a new DIMM in a socket, remove first any previously installed DIMM from that socket. Important: Before removi

Página 167 - Screw types used

3 System upgrade68Installing a DIMM 1 Observe the ESD precautions and pre-installation instructions described on page 35.2 Locate the DIMM sockets on

Página 168

69To reconfigure the system memory:The system automatically detects the amount of memory installed. Run the BIOS setup to view the new value for total

Página 169

viiiInstalling an additional hard disk into the HDD cage carrier 53Replacing the CD-ROM drive 55Installing 5.25-inch drives 57Upgrading the processor

Página 170

3 System upgrade70Installing an expansion cardThis section explains how to install an expansion card. The onboard expansion slots supports PCI (Perip

Página 171

718 Press the PCI slot release latch on the rear panel of the server (4). 9 Observe the post-installation instructions described on page 36. Note: Wh

Página 172

3 System upgrade72Upgrading the power supply The Altos G530 system may ship out with a redundant or non-redundant power supply module. Installing a r

Página 173

731 Remove the cover of the empty power supply module bay.Note: If the system ships out with a screw on the cover, remove the screw first then detach

Página 174

3 System upgrade742 Hold the handle on front of the power supply module while pressing your thumb on the release latch. Slide the power supply module

Página 175

75Installing a non-redundant power supply moduleThe Altos G530 power subsystem accepts a 600-watt non-redundant power supply module. If you are replac

Página 176

3 System upgrade765 Slide the new power supply module into the bay, then secure it to the chassis with the four screws removed earlier.6 Attach the p

Página 177

4 BIOS setup

Página 178

This chapter gives information about the system BIOS and discusses how to configure the system by changing the settings of the BIOS parameters.

Página 179 - Configuring the SATA RAID

79BIOS setup BIOS setup is a hardware configuration program built into the system's Basic Input/Output System (BIOS). Since most systems are alre

Página 180 - Creating a RAID 1 volume

ix5 Troubleshooting 121Resetting the system 123Problems following initial system installation 124First steps checklist 125Hardware diagnostic testing

Página 181

4 BIOS setup80Entering BIOS setupPower on the server to start the system POST process. During bootup, press F2 to enter the BIOS setup screen. Note:

Página 182

81•Press F1 for General Help on using the BIOS setup.•Press F10 to save changes and close the BIOS setup.•Press Esc to close the BIOS setup.In the des

Página 183

4 BIOS setup82MainThe Main menu displays basic and important information about the system. These information are necessary for troubleshooting and ma

Página 184

83Processor Speed The processor speed is the speed at which a microprocessor executes instructions. Clock speeds are expressed in megahertz (MHz), wit

Página 185

4 BIOS setup84AdvancedThe Advanced menu contains parameter values that define how the system behaves on startup.Warning! Be cautious in setting param

Página 186 - RAID volume initialization

85Processor ConfigurationThe Processor Configuration submenu displays CPU settings such as type, actual speed, cache size and other CPU related settin

Página 187 - Initializing a RAID volume

4 BIOS setup86CPU 2 CPUID ID number of the CPU 2. CPU 2 Cache L1 Indicates CPU 2 cache L1 size.CPU 2 Cache L2 Indicates CPU 2 cache L2 size.Max CPUI

Página 188

87HT Technology in MPSWhen Enabled, adds secondary processor threads to the MPS (multiprocessor) table for the pre-ACPI (pre- Advanced Configuration a

Página 189

4 BIOS setup88IDE ConfigurationThe IDE Configuration submenu lets you define the parameter settings related to the hard disk/s. Parameter Desc

Página 190

89Configure S-ATA as RAIDWhen set to Enabled, the SATA channels are reserved to be used as RAID.DisabledEnabledS-ATA Ports DefinitionDefines priority

Comentários a estes Manuais

Sem comentários